Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Sci Rep ; 11(1): 16936, 2021 08 19.
Article in English | MEDLINE | ID: covidwho-1366827

ABSTRACT

The COVID-19 pandemic has created an urgent need for robust, scalable monitoring tools supporting stratification of high-risk patients. This research aims to develop and validate prediction models, using the UK Biobank, to estimate COVID-19 mortality risk in confirmed cases. From the 11,245 participants testing positive for COVID-19, we develop a data-driven random forest classification model with excellent performance (AUC: 0.91), using baseline characteristics, pre-existing conditions, symptoms, and vital signs, such that the score could dynamically assess mortality risk with disease deterioration. We also identify several significant novel predictors of COVID-19 mortality with equivalent or greater predictive value than established high-risk comorbidities, such as detailed anthropometrics and prior acute kidney failure, urinary tract infection, and pneumonias. The model design and feature selection enables utility in outpatient settings. Possible applications include supporting individual-level risk profiling and monitoring disease progression across patients with COVID-19 at-scale, especially in hospital-at-home settings.


Subject(s)
COVID-19/epidemiology , Models, Statistical , SARS-CoV-2/physiology , Aged , Aged, 80 and over , Biological Specimen Banks , COVID-19/mortality , Cohort Studies , Comorbidity , Female , Humans , Machine Learning , Male , Middle Aged , Pandemics , Prognosis , Risk Factors , United Kingdom/epidemiology
2.
Sensors (Basel) ; 21(4)2021 Feb 20.
Article in English | MEDLINE | ID: covidwho-1106111

ABSTRACT

The standard deviation of the interval between QRS complexes recorded over 24 h (SDNN24) is an important metric of cardiovascular health. Wrist-worn fitness wearable devices record heart beats 24/7 having a complete overview of users' heart status. Due to motion artefacts affecting QRS complexes recording, and the different nature of the heart rate sensor used on wearable devices compared to ECG, traditionally used to compute SDNN24, the estimation of this important Heart Rate Variability (HRV) metric has never been performed from wearable data. We propose an innovative approach to estimate SDNN24 only exploiting the Heart Rate (HR) that is normally available on wearable fitness trackers and less affected by data noise. The standard deviation of inter-beats intervals (SDNN24) and the standard deviation of the Average inter-beats intervals (ANN) derived from the HR (obtained in a time window with defined duration, i.e., 1, 5, 10, 30 and 60 min), i.e., ANN=60HR (SDANNHR24), were calculated over 24 h. Power spectrum analysis using the Lomb-Scargle Peridogram was performed to assess frequency domain HRV parameters (Ultra Low Frequency, Very Low Frequency, Low Frequency, and High Frequency). Due to the fact that SDNN24 reflects the total power of the power of the HRV spectrum, the values estimated from HR measures (SDANNHR24) underestimate the real values because of the high frequencies that are missing. Subjects with low and high cardiovascular risk show different power spectra. In particular, differences are detected in Ultra Low and Very Low frequencies, while similar results are shown in Low and High frequencies. For this reason, we found that HR measures contain enough information to discriminate cardiovascular risk. Semi-continuous measures of HR throughout 24 h, as measured by most wrist-worn fitness wearable devices, should be sufficient to estimate SDNN24 and cardiovascular risk.

SELECTION OF CITATIONS
SEARCH DETAIL